Toho-electronics TTM-339 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Toho-electronics TTM-339. TOHO ELECTRONICS TTM-339 User Manual [ru] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
- 1 -
TOHO ELECTRONICS INC.
Program Controller TTM-339
Operation Manual
Thank you for purchasing Toho Electronics TTM-339 series.
Before using the products, thoroughly read this manual for a better understanding of them.
Ensure to store this manual and use it whenever needed.
Contents
1.Precautions on the use of the products
2.Parts indication and Installation ・・ P4
3.Terminal connection diagram・・・ P7
4.Terms and various functions P8
Flow of mode change operation and run operation
Measurement range and indicator resolution
List of models
Standard specifications ・・
Maintenance and Inspections P31
Przeglądanie stron 0
1 2 3 4 5 6 ... 31 32

Podsumowanie treści

Strona 1 - Operation Manual

- 1 - TOHO ELECTRONICS INC. Program Controller TTM-339 Operation Manual Thank you for purchasing Toho Electronics’ TTM-339 series. Befo

Strona 2 - ★ Alarm symbols

- 10 - 4.8 Time signal output At starting each step, the time signals 1 to 4 are turned on upon elapse of the time set on the ON delay timer.

Strona 3 - ★ Summary notation

- 11 - The step changes when the external contact open (OFF) changes to the external contact closed (ON) during a program run. 4.11.4 Patter

Strona 4 - 2.3 Key

- 12 - 4.13.2 Operation amount current limiter The operation amount and current value are limited at each point obtained by dividing SLL to SLH i

Strona 5 - 2.6 Outer Dimensions

- 13 - Example: Assume the following for various settings and PV: PV = 120 C, operation amount limiter point 2 = 75.0%, current value limiter poi

Strona 6

- 14 - 4.14.3-2 Primary/secondary control operation amount increase time Setting items: Primary/secondary control operation amount increase time

Strona 7 - Precautions on wiring

- 15 - 4.16 PV filter setting 4.16.1 PV filter setting This setting is a function to achieve the CR filter effect on the software by performin

Strona 8

- 16 - 4.17 Event alarm By setting the events 1 to 4 function setting, outputs of EV 1 to 4 are turned on if PV is located within the alarm range

Strona 9

- 17 - 4.20 Electric Power Outage Function  Upon recovery of the electric power after its outage during a run, the status at the time of the ou

Strona 10

- 18 - 5. Flow of Mode Change Operation and Run Operation 5.1Primary Power Source in the OFF status5.2Initial modePrimary power source ON5.3Norm

Strona 11 - - 11

- 19 - Flow of the program setting mode Pattern No. setting modeMODE keyStep 1 temperature settingStep 1 time settingStep 2 temperature settingSt

Strona 12 - Operation amount

- 2 - 1.Precautions on the use of the products Ensure to read this manual before using the equipment. Take care to understand the following for th

Strona 13 - - 13

- 20 - Flow of the Common parameter setting mode Normal mode△ keyMODE keyMODE keyMODE keyMODE key: 3 secondsMODE keyMODE keyMODE keyMODE keyMODE k

Strona 14 - 4.15 Key lock

- 21 - 5.1 List of settings in the pattern No. setting and program setting modes Name Setting content Initial value 1 SV * Setting temperature

Strona 15 - - 15

- 22 - 5.5 Common parameter setting mode SET 4 (1) SET04 Name Setting content Initial value 1 SLH SV limiter upper limit (*2) (*3) Thermo

Strona 16

- 23 - 5.5 Common parameter setting mode SET 4 (2) SET04 Name Setting content Initial value 31 MV2 Secondary control operating amount 0.

Strona 17 - 1) 2) 3)

- 24 - 5.6 Common parameter setting mode SET 5 to 8 SET05 to SET08 Name Setting content Initial value 1 E*F1 Event function 1 setting Fun

Strona 18 - - 18

- 25 - 5.7 Common parameter setting mode SET 9 (2) SET09 Name Setting content Initial value With the selection of [MLF = 2,3], the followi

Strona 19 - Pattern No. setting mode

- 26 - 5.8 Common parameter setting mode SET 10 SET10 Name Setting content Initial value 1 INP1 Input type setting (*2) (*3) 0 K thermocoup

Strona 20

- 27 - 5.10 Common parameter setting mode SET 12 SET12 Name Setting content Initial value 1 PRT Communication protocol setting Press the MO

Strona 21

- 28 - 5.12 List of the alarm temperature setting mode setting Name Setting content Initial value 1 E1H Event 1 upper limit setting See

Strona 22 - Initial value

- 29 - 7. List of models TTM-339-□ □-□□□□□□ ① ② ③ Symbol Item Description Size 96 x

Strona 23

- 3 - Turn off the power supply before cleaning the equipment, and wipe it with a soft dry cloth. Do not use thinners, as they may cause defor

Strona 24 - - 24

- 30 - Display/ Setting Display type LCD lamp red 15 pcs RUN,OUT,EV1,EV2,EV3,EV4、TS1,TS2,TS3,TS4,TIME,AUTO,MANU,AT,END LCD lamp

Strona 25

- 31 - 9.MAINTENANCE AND INSPECTIONS If any of the troubles still exists after following the above instruction, or for any other cases, contact ou

Strona 26 - - 26

- 32 - TOHO ELECTRONICS INC. WEB.site http://www.toho-inc.com E-mail [email protected] Head of

Strona 27 - - 27

- 4 - 2. Parts indication and Installation 2.1 Full panel face 2.2 Segment display section No. Segment character C

Strona 28

- 5 - 2.4 Lamp display section Lamp character Content PTN Lights up while a pattern in display. STP Lights up while a step in display. RU

Strona 29 - 8. STANDARD SPECIFICATIONS

- 6 - 2.7 Precautions on installation Warning Ensure to turn the power supply off before beginning removal or reinstallation of the equipment in

Strona 30 - - 30

- 7 - 3. Terminal connection diagram Power supply 100 to 240 VAC ① X A Communications RS-485 ⑬  EV4 Open collector output ② B ⑭  TS1 Not in

Strona 31 - LOC Indication

- 8 - The use of shielded wires is recommended. For Pt100 (resistance temperature detector), use identical wires of low lead resistance and no

Strona 32 - TOHO ELECTRONICS INC

- 9 - 4.4 Wait function For the current step transferring to the next step, the next step does not begin if PV has not reached the wait zone (si

Komentarze do niniejszej Instrukcji

Brak uwag