4.2 Examples of communications to be written
Example: Request message: This requests this product set at address 03 to set "the A1F setting to
(High-level computer) 135" (write 135).
(Set the event 1 function to the following: Error alarm type to be PV
error alarm 1, alarm type to be deviation lower limit alarm 3 and
additional function to be alarm hold + standby sequence (5).)
In response to that,
Response message: This returns a notice that the request message has been received.
(This product)
*Check that it has been written by reading the data separately.
Write request message (transmitted from a high-level computer)
Code Code, data ASCII code, note 2)
Start code STX 02H
Address 03 32H 33H
Request contents W (Write) 57H
Identifier, note 1) A2F 41H 33H 46H
Numerical data 00135 30H 30H 31H 33H 35H
End code ETX 03H
BCC data request 56H
response 04H
Acknowledge code ACK 06H
Note 1): See "7. Table of identifiers (codes)."
Note 2): For the ASCII codes, see "8. Table of ASCII codes."
Response message (returned from this product)